Gilbarco Sk700 Programming Manual: A Comprehensive Guide
The Gilbarco SK700 is a popular point-of-sale (POS) system used in various retail fueling applications, including gas stations and convenience stores. The system is designed to manage fuel sales, inventory, and customer transactions efficiently. However, to get the most out of the SK700, it's essential to understand its programming and configuration. This article provides an in-depth look at the Gilbarco SK700 programming manual, covering its key features, setup, and troubleshooting.
Overview of the Gilbarco SK700
The Gilbarco SK700 is a versatile POS system that offers a range of features to streamline fuel sales, inventory management, and customer transactions. Some of its key features include:
Gilbarco SK700 Programming Manual: Importance and Purpose
The Gilbarco SK700 programming manual is a critical resource for system administrators, technicians, and users who need to configure and maintain the POS system. The manual provides detailed instructions on how to:
Key Components of the Gilbarco SK700 Programming Manual
The Gilbarco SK700 programming manual covers various aspects of system configuration and maintenance. Some of the key components include:
Step-by-Step Guide to Programming the Gilbarco SK700
Programming the Gilbarco SK700 requires a thorough understanding of the system's configuration and settings. Here's a step-by-step guide to help you get started:
Troubleshooting Common Issues
While the Gilbarco SK700 is a reliable POS system, users may encounter issues during programming or operation. Here are some common issues and troubleshooting tips:
Conclusion
The Gilbarco SK700 programming manual is a comprehensive resource for system administrators, technicians, and users who need to configure and maintain the POS system. By understanding the system's configuration and settings, you can optimize fuel sales, inventory management, and customer transactions. This article provides a detailed guide to the Gilbarco SK700 programming manual, covering its key features, setup, and troubleshooting. Whether you're a new user or an experienced technician, this article aims to provide valuable insights and practical guidance to help you get the most out of your Gilbarco SK700 system. Gilbarco Sk700 Programming Manual
Important: The official SK‑700 Programming Manual is copyrighted material owned by Gilbarco Glen Research. I can’t reproduce any of its text or graphics, but I can tell you what topics it contains, how the workflow generally proceeds, and where you can legally obtain a copy. If you need a specific procedure (e.g., “how to change the price‑grade table”), let me know and I can walk you through it step‑by‑step using the public knowledge that’s widely shared among pump technicians.
| Symptom | Likely Cause | Fix | |---------|--------------|-----| | Pump refuses to start after a price change | Missing tax code or invalid effective‑date format. | Use the host’s Validate button; ensure all mandatory fields are filled. | | “Communication timeout” error | Wrong cable (DB‑9 vs RJ‑45), mismatched baud rate (9600 N,8,1 for RS‑232), or Ethernet IP conflict. | Verify cable type, set host software to the correct COM port/baud, confirm IP address is in the same subnet. | | Nozzle does not dispense | Mapping points to a grade that isn’t enabled in the Price Table. | Ensure the grade code appears in the price‑grade matrix and has a non‑zero price. | | Firmware upgrade fails at 80 % | Power fluctuation during flash. | Use an UPS or stable power source; avoid using the pump while flashing. | | Lost configuration after power loss | The EEPROM backup option is disabled. | Enable Persistent Storage under System → Settings → EEPROM and re‑save the configuration. |
Before diving into the manual itself, it's important to understand the hardware. The SK700 is an electronic dispenser control console designed for:
It manages up to 16 fueling positions (hoses), integrates with submersible pumps, handles authorization (card readers or remote POS), and logs transaction data. The programming manual is the blueprint for configuring all of these functions.
The SK700 can handle dual or triple hoses. The programming manual details how to assign a logical "grade" (Regular, Plus, Premium) to a physical hose.
G 1.G 1 (Grade 1), G 2, G 3.Without the official Gilbarco SK700 Programming Manual (typically part number MDE-4289 or similar), operators face:
The manual provides step-by-step procedures for setup, calibration, diagnostics, and compliance with weights & measures regulations.
Programming a device like the Gilbarco SK700 requires a detailed understanding of its technical specifications, the site's operational requirements, and compliance with relevant security standards. Always refer to the official documentation and seek support from the manufacturer or qualified professionals if needed.
Programming the Gilbarco SK700 and SK700-2 requires a master code (often 0128) and specific command codes initiated by pressing F1, with critical parameters like country code, pump type, and protocol set immediately following a cold start . Physical calibration switches and USB configuration options allow for detailed metrological and operational adjustments, while command codes manage price, communication, and error logging . For complete official procedures, consult the manuals available through Gilbarco at docs.gilbarco.com. SK700-2 Cold Start Re-Configure (Apollo) - Kentronics
Understanding the Gilbarco SK700 Programming Manual The Gilbarco SK700 and its successor, the SK700-II, are among the most reliable and widely used fuel dispensers globally. However, for a station owner or technician, accessing the "brains" of the pump requires a solid understanding of the programming manual and the specific command codes used to configure the unit.
Whether you are performing a new installation or adjusting prices, this guide breaks down the essential elements of the Gilbarco SK700 programming process. 1. Accessing the Programming Mode
To make any changes to the SK700, you must first enter the Service Mode. Unlike consumer electronics, fuel dispensers require a physical or electronic "key" to prevent unauthorized tampering with weights and measures.
The Command Console: Most programming is done via the manager’s keypad or a handheld remote programmer. Gilbarco Sk700 Programming Manual: A Comprehensive Guide The
Security Switch: Inside the pump head, there is typically a "Calibration" or "Program" switch that must be toggled to allow permanent changes to metrology settings. 2. Navigation and Command Structure
The SK700 uses a Command-Sub-code system. You enter a primary code to select a category (like "Price" or "System Configuration") and then a sub-code to drill down to specific settings. Common Function Codes:
Level 1 (Manager Level): General stats, such as totals and basic price changes.
Level 2 (Technician Level): Configuration of hydraulic types, blend ratios, and vapor recovery settings.
Level 3 (Weights & Measures): Calibration of the meters (requires breaking the physical seal). 3. Key Programming Tasks Unit Price Programming
One of the most frequent uses for the manual is changing the price per litre or gallon. Enter the manager code. Navigate to the Price Change command (usually command 1). Select the specific Grade or Hose. Input the new price and press Enter to confirm. Calibration and Metering
If the pump is dispensing slightly more or less than the display shows, you must calibrate the meter. The SK700 manual outlines the "K-Factor," which is the electronic pulse count per unit of fuel. Adjusting this value ensures the pump remains accurate and legal for trade. Error Code Diagnostics
The programming manual is also a diagnostic tool. When the pump displays a "Fail" message, you can use the command console to pull the Error Log. Common codes include: Error 20: Pulser failure.
Error 31: Communication timeout with the Point of Sale (POS) system. Error 50: Internal memory error. 4. Safety and Compliance Warning
Programming a Gilbarco SK700 is not just a technical task; it is a legal one. In most jurisdictions:
Sealing: Any change to the volume measurement must be reported to local Weights and Measures authorities.
Safety: Always ensure the power is off or the pump is in a safe state before opening the cabinet to access the programming switches.
The Gilbarco SK700 Programming Manual is an indispensable tool for maintaining fuel accuracy and operational efficiency. While basic price changes can be done by a manager, complex configuration and calibration should always be handled by a certified technician to ensure compliance with safety and trade regulations. Fuel Sales Management : The SK700 allows you
To develop or program a feature on a Gilbarco SK700 dispenser, you must access the programming mode through the manager keypad using specific security codes. Accessing Programming Mode
Most "features" or configuration settings are reached by entering the Manager Functions Initialize : Press the key on the manager keypad. Security Code : Enter the master security code, typically , then press Command Input
: The unit enters function mode (often indicated by a "0" on the display), allowing you to input specific Function Codes Common Programming Features & Function Codes
The following codes are used to configure or "develop" specific dispenser behaviors: Kentronics PPU (Price Per Unit) Settings : Used to set or change fuel prices directly at the pump. Maximum Allocation
: Set limits on the maximum volume or amount a customer can dispense in one transaction. Pulse Channel Configuration Function Code 9 : Set the start position of pulse channels (High or Low). Function Code 10
: Set the pulse format (e.g., Channel B lags Channel A by 90°). Communication Timeout Code 40.22
to adjust the PPU communications timeout (default is 10 seconds, often increased to 30 seconds for specific setups). Country Code
allows you to set the country (e.g., "36" for Australia), which automatically loads regional default configurations. This can typically only be done after a Cold Start Kentronics Advanced Feature Deployment
For more complex feature integration, such as multimedia or payment systems: USB Configuration
: On Apollo CPU boards, a special USB stick can be used to "Get Config" (Code 8) or "Send New Software" to the pump while in CRIND (Card Reader in Dispenser) : Advanced features like Gilbarco FlexPay™ Applause™ Media System
require a separate diagnostic startup menu accessed via the FlexPay EPP. Note on Safety
: Any procedure requiring internal electronics access necessitates a total electrical shut-off to the unit to prevent fire or explosion. specific feature
(e.g., price changes, pulse settings, or communication protocols) are you trying to configure or develop for the SK700? Programming SK700/SK700-2 Gilbarco | PDF - Scribd