The DIGI SM-5300 is a PC-based weigh-labeller designed for retail environments, featuring high-speed printing and a user-friendly interface. This guide covers the essential manual operations for daily use. 1. Initial Setup & Powering On

Power Toggle: Locate the power switch (usually underneath or on the side of the base) and turn it on.

Initialization: Wait for the system to boot to the main registration screen. Ensure the scale platter is clear of any items during this process to allow for proper zero calibration. Zeroing: If the display does not show 0.0000.000 , press the [ZERO] key to reset the baseline weight. 2. Loading Labels

The SM-5300 often uses linerless labels with an auto-cutter feature to reduce waste . Open the printer cover (usually on the side of the unit). Remove the empty label roll core.

Insert a new roll, ensuring the thermal side (printable side) faces the print head. Feed the label edge through the auto-cutter and sensors.

Close the cover firmly; the scale should automatically detect the label size and align the paper . 3. Weighing & Labeling Operations

Manual PLU Entry: Type the PLU (Price Look-Up) number using the numeric keypad and press the [PLU] key.

Preset Keys: For high-volume items, use the touchscreen or physical preset keys to select a product instantly. Tare Weight Setup: digi sm5300b manual work

One-Touch Tare: Place an empty container on the scale and press [TARE]. The scale will subtract this weight from the total .

Digital Tare: If you know the weight of the container, type the value (e.g., ) and press [TARE] .

Printing: Once the weight stabilizes, the scale will automatically print the label (if in "Auto" mode) or wait for you to press the [PRINT] key. 4. Daily Maintenance

Print Head Cleaning: Use a thermal head cleaning pen or a soft cloth with isopropyl alcohol to wipe the print head daily to prevent streaks and maintain barcode readability.

Scale Platter: Remove and wipe down the stainless steel platter with a damp cloth to prevent debris buildup.

Cutter Maintenance: Periodically check the auto-cutter for adhesive buildup, especially when using linerless labels. 5. Troubleshooting Common Issues

"Scale Not Stable": Ensure the scale is on a flat, vibration-free surface and that no fans are blowing directly on the platter. The DIGI SM-5300 is a PC-based weigh-labeller designed

"Paper Jam": Open the printer compartment and check for labels stuck to the rollers or cutter blade.

"No Label Detected": Ensure the label roll is seated correctly and that the paper sensor is not blocked by dust.

For detailed technical adjustments or network configurations, you can refer to the official SM-5300 Service Manual for deeper PC-scale printer settings .

Operating the DIGI SM-5300B (Bench model) manually involves navigating its 7-inch WVGA color touch screen

to manage weighing, labeling, and product data. This PC-based scale is designed for high-traffic retail environments like markets and bulk-buy shops where flexibility is essential. DIGI (TERAOKA) Basic Weighing & Labeling Select an Item (PLU) Preset Keys

: Tap the programmed buttons on the left side of the operator screen. Manual Entry : Type the PLU number using the on-screen numeric keypad and press the Weigh the Product : Place the item on the load cell. Print Label Manual Mode : Press the button (bottom right) after the weight stabilizes. Prepack Mode : If enabled, the scale will automatically print

a label as soon as a stable weight is detected, allowing for faster processing of multiple items. Managing Product Data (PLU Programming) You can manually add or update items directly on the scale: Create New PLU : Enter the PLU Programming Default: 600A / 50mV Manual calculation: If your

, and type a unique number. If it doesn't exist, the system will prompt you to create it. Edit Fields : Use the touchscreen to fill in the Product Name Unit Price (per kg or piece), and (usually matching the PLU for POS compatibility). : Enter the Best-before

date by inputting the number of days from the current pack date. Ingredients & Messages

: Manually type ingredients or select "Special Messages" like "Keep Frozen" from a pre-defined list. Linerless Label Loading The SM-5300B often uses linerless labels with an auto-cutter to reduce waste. DIGI (TERAOKA) Open Cassette

: Push the green button/lever to the left to open the front door. Insert Roll : Place the label roll over the green bezel. Thread & Close

: Pull the paper through the "goal posts" (alignment guides) and close the door. Label Feed

icon (arrow pointing to a label) on the screen to align the paper for the first print. Key Features for Operators PC-Based Scales SM-5300B Case Studies BOB & ROY'S | DIGI

Document Title: Technical Report on Manual Work Procedures for the Digi SM5300B Module
Target Audience: Embedded Hardware Engineers, Technicians, Integration Specialists
Purpose: To outline the necessary manual handling, setup, and troubleshooting steps for the Digi SM5300B as derived from its product manual.


4.2. Shunt Rating (P-01)

Task B: Manual Tare (Net Weight Calculation)

The most common manual work is setting a tare.

  1. Place the empty container on the scale.
  2. Press TARE. The display resets to 0 and "NET" appears.
  3. Add the product. The display now shows only the product weight.
  4. To clear the tare, remove everything and press TARE again.

Manual override: You can also enter a known tare value via the numeric keypad. Press TARE, type the value (e.g., 0.500 for 500g), then press TARE again.

Common manual tasks